services.apcupsd.hooks
Each attribute in this option names an apcupsd event and the string value it contains will be executed in a shell, in response to that event (prior to the default action). See "man apccontrol" for the list of events and what they represent.
A hook script can stop apccontrol from doing its default action by exiting with value 99. Do not do this unless you know what you're doing.
- Type
attribute set of strings concatenated with "\n"- Default
{ }- Example
{ doshutdown = "# shell commands to notify that the computer is shutting down"; }- Declared
- <nixpkgs/nixos/modules/services/monitoring/apcupsd.nix>